{"id":2244,"date":"2024-08-14T17:19:57","date_gmt":"2024-08-14T17:19:57","guid":{"rendered":"https:\/\/www.mainmind.com\/blog\/?p=2244"},"modified":"2024-09-16T10:51:01","modified_gmt":"2024-09-16T10:51:01","slug":"todos-los-usb-dejan-de-funcionar-en-servidor-hpe-proliant","status":"publish","type":"post","link":"https:\/\/www.mainmind.com\/blog\/todos-los-usb-dejan-de-funcionar-en-servidor-hpe-proliant\/","title":{"rendered":"Todos los USB dejan de funcionar en servidor HPE Proliant"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Ni los frontales ni los traseros&#8230; ninguno&#8230; se realiz\u00f3 mantenimiento de firmwares, BIOS, drivers&#8230; mediante la utilidad <a href=\"https:\/\/www.hpe.com\/es\/es\/servers\/smart-update.html\" data-type=\"link\" data-id=\"https:\/\/www.hpe.com\/es\/es\/servers\/smart-update.html\">Smart Update Manager<\/a> (SUM) pero segu\u00eda igual&#8230; <\/p>\n\n\n\n<!--more-->\n\n\n\n<p class=\"wp-block-paragraph\">Existe un <a href=\"https:\/\/support.hpe.com\/hpesc\/public\/docDisplay?docId=sf000069385en_us&amp;docLocale=en_US&amp;page=index.html\" data-type=\"link\" data-id=\"https:\/\/support.hpe.com\/hpesc\/public\/docDisplay?docId=sf000069385en_us&amp;docLocale=en_US&amp;page=index.html\">documento del fabricante explicando los pasos a seguir<\/a> para ProLiant DL360 Gen10 aunque con otra versi\u00f3n de BIOS e ILO en el que se indica descargar por completo la energ\u00eda del servidor y realizar un borrado de la NVRAM&#8230; todo este procedimiento, salvo el apagado f\u00edsico inicial de las fuentes de alimentaci\u00f3n y esperar unos minutos (power drain), se ha realizado con conexi\u00f3n remota al iLO 5 v3.01<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Entraremos en la BIOS con la opci\u00f3n \u00ab<em>F10 Intelligent Provisioing<\/em>\u00ab:<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"673\" src=\"https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/00-1024x673.jpg\" alt=\"00 sobre NVRAM_HPE\" class=\"wp-image-2250\" style=\"width:960px\" srcset=\"https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/00-1024x673.jpg 1024w, https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/00-300x197.jpg 300w, https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/00-768x505.jpg 768w, https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/00.jpg 1342w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Una vez se carga la interfaz web, seleccionamos \u00ab<em>Realizar mantenimiento<\/em>\u00ab<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"449\" src=\"https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/01-1024x449.jpg\" alt=\"01 sobre NVRAM_HPE\" class=\"wp-image-2251\" style=\"width:960px\" srcset=\"https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/01-1024x449.jpg 1024w, https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/01-300x132.jpg 300w, https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/01-768x337.jpg 768w, https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/01.jpg 1343w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Entramos en \u00ab<em>Configuraci\u00f3n r\u00e1pida<\/em>\u00ab:<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"610\" src=\"https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/02-1024x610.jpg\" alt=\"02 sobre NVRAM_HPE\" class=\"wp-image-2253\" style=\"width:960px\" srcset=\"https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/02-1024x610.jpg 1024w, https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/02-300x179.jpg 300w, https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/02-768x458.jpg 768w, https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/02.jpg 1327w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">En la primera pantalla encontramos la opci\u00f3n \u00ab<em>Click Reset BIOS<\/em>\u00ab<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"631\" src=\"https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/03-1024x631.jpg\" alt=\"03 sobre NVRAM_HPE\" class=\"wp-image-2252\" style=\"width:960px\" srcset=\"https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/03-1024x631.jpg 1024w, https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/03-300x185.jpg 300w, https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/03-768x473.jpg 768w, https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/03.jpg 1327w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Intentando realizar el reinicio desde la pantalla remota de iLO puede dar error, en este caso forzamos \u00abCold boot\u00bb desde el men\u00fa principal:<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"179\" src=\"https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/03b-1024x179.jpg\" alt=\"03b sobre NVRAM_HPE\" class=\"wp-image-2248\" style=\"width:960px\" srcset=\"https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/03b-1024x179.jpg 1024w, https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/03b-300x52.jpg 300w, https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/03b-768x134.jpg 768w, https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/03b.jpg 1508w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">En el nuevo arranque (tardar\u00e1 algo m\u00e1s) aparecer\u00e1 alguna comprobaci\u00f3n adicional y se muestra \u00abUSB Controller Initialization\u00bb:<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"725\" height=\"140\" src=\"https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/04.jpg\" alt=\"04 sobre NVRAM_HPE\" class=\"wp-image-2246\" style=\"width:643px;height:auto\" srcset=\"https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/04.jpg 725w, https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/04-300x58.jpg 300w\" sizes=\"auto, (max-width: 725px) 100vw, 725px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"644\" height=\"594\" src=\"https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/04b.jpg\" alt=\"04b sobre NVRAM_HPE\" class=\"wp-image-2247\" srcset=\"https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/04b.jpg 644w, https:\/\/www.mainmind.com\/blog\/wp-content\/uploads\/2024\/NVRAM_HPE\/04b-300x277.jpg 300w\" sizes=\"auto, (max-width: 644px) 100vw, 644px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">La prueba se realiz\u00f3 sobre Windows Server 2022 y el equipo volvi\u00f3 a iniciar sin mayor problema con los USBs funcionando de nuevo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Como alternativa existe la opci\u00f3n de utilizar el switch f\u00edsico de mantenimiento en la placa base del servidor:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Apagar servidor y abrir la tapa superior<\/li>\n\n\n\n<li>Cambiar la posici\u00f3n S6 a ON (en la tapa del servidor se indica d\u00f3nde encontrar los interruptores de mantenimiento)<\/li>\n\n\n\n<li>Iniciar servidor y esperar el mensaje que indica volver a cambiar a OFF el interruptor:<br>\u00ab<em>Maintenance switch detected in the ON position. The system is being default configured. This may take a few minutes\u2026 Power off the server and toggle the maintenance switch to the OFF position.<\/em>\u00ab<\/li>\n\n\n\n<li>Apagar servidor de nuevo<\/li>\n\n\n\n<li>Cambiar la posici\u00f3n S6 a OFF<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>Ni los frontales ni los traseros&#8230; ninguno&#8230; se realiz\u00f3 mantenimiento de firmwares, BIOS, drivers&#8230; mediante la utilidad Smart Update Manager (SUM) pero segu\u00eda igual&#8230;<\/p>\n","protected":false},"author":1,"featured_media":2127,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3],"tags":[980,814,850,978,979],"class_list":["post-2244","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-hardware","tag-bios","tag-hpe","tag-hpe-proliant","tag-nvram","tag-usb"],"_links":{"self":[{"href":"https:\/\/www.mainmind.com\/blog\/wp-json\/wp\/v2\/posts\/2244","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mainmind.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mainmind.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mainmind.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mainmind.com\/blog\/wp-json\/wp\/v2\/comments?post=2244"}],"version-history":[{"count":3,"href":"https:\/\/www.mainmind.com\/blog\/wp-json\/wp\/v2\/posts\/2244\/revisions"}],"predecessor-version":[{"id":2257,"href":"https:\/\/www.mainmind.com\/blog\/wp-json\/wp\/v2\/posts\/2244\/revisions\/2257"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.mainmind.com\/blog\/wp-json\/wp\/v2\/media\/2127"}],"wp:attachment":[{"href":"https:\/\/www.mainmind.com\/blog\/wp-json\/wp\/v2\/media?parent=2244"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mainmind.com\/blog\/wp-json\/wp\/v2\/categories?post=2244"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mainmind.com\/blog\/wp-json\/wp\/v2\/tags?post=2244"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}